Instant Replay Power Supply Cable Pinout

Instant Replay Power Supply Cable Pinout

Instant Replay Power Supply Cable Pinout

Applies to:  

CAUTION:  THIS ARTICLE CONTAINS INFORMATION ON TESTING POWER SUPPLIES.    POWER SUPPLIES CONTAINED IN THIS UNIT HAVE BOTH LINE VOLTAGE AND HIGH VOLTAGE.   CONDUCTING TESTING WITH POWER CONNECTED SHOULD ONLY BE DONE BY A TRAINED PROFESSIONAL.  SEVERE INJURY OR DEATH MAY OCCUR IF TESTING IS CONDUCTED INCORRECTLY.

Instant Replay models DR-600, DR-554, DR-552.

Symptom:

Various power / no power related issues.

Possible Reason(s): 

Low or no voltages coming from either the main switching power supply or the linear power supply.

Solution(s):

CAUTION:  POWER SUPPLIES CONTAINED IN THIS UNIT HAVE BOTH LINE VOLTAGE AND HIGH VOLTAGE ON EXPOSED RAILS.   CONDUCTING TESTING WITH POWER CONNECTED SHOULD ONLY BE DONE BY A TRAINED PROFESSIONAL.  SEVERE INJURY OR DEATH MAY OCCUR IF TESTING IS CONDUCTED INCORRECTLY.

Check voltages as follows:

Switching power supply:   J6 connector on main board.

NOTE: When checking power on this supply, the supply must be under load.

On the Instant Replay product, the following chart describes the pinout for the main DC power cable.

Pin Color Voltage
1 Yellow +12V
2 Red +5V
3 Red +5V
4 Black GND
5 Black GND
6 Purple -12V

Note: The power supply used in these systems is an Emerson LPT-42.  The replacement fuse is listed as a Littefuse F2.5AH, 250V, Type 21602.5 .