SD MAXX RAID Setup and Software Install
SD MAXX RAID Setup and Software Install
- Disable Quiet Boot
- Power on the Server.
- Enter BIOS setup by pressing [DEL] at prompt.
- Change Quiet Boot to [Disabled].
- Press [F10] to save changes.
- Server will re-boot.
- Rebuild RAID Array
- Press [Alt–3] at prompt to enter 3ware setup.
- Press [Enter] to continue.
- Press [ENTER] to select Drives.
- Press [Tab] and select Create Unit.
- Select RAID Configuration.
Select RAID 5.
- Select StorSave Profile and set to Performance.
- Select Auto–Verify and set to Disabled.
- Press [Tab] to select Advanced and press [Enter].
- Set Drive Queuing Mode to Enabled.
- [Tab] to OK and press [Enter].
- Select OK, Type [Y] to enable Write Cache.
- Press [F8] and type [Y] to Save and Exit. Server will re-boot.
- Reconfigure BIOS
- Enter BIOS setup by pressing [DEL] at prompt.
- Change Quiet Boot back to [Enabled].
- Navigate to Boot Options.
- Select Boot Option #1 and set to 3ware Storage Controller.
- Press [F10] and press [ENTER] to select Yes to save and exit.
- Install Software
- Insert CD Software Drive.
- Server will automatically boot from USB drive.
- Installation Options screen will appear.
- Select Full Install and press [Enter].
- Confirmation screen will appear.
- Select Yes and press [Enter] to begin installation.
- Installation Options screen will reappear.
- Select Full Install and press [Enter].
- Confirmation screen will appear.
- Select Yes and press [Enter] to install software.
- When installation is complete, remove USB drive and press [Enter] to select OK. Server will re-boot.
- Verify RAID
- Navigate to end of EULA and click Accept.
- Click Start>RAID Status.
- Select Accept this certificate permanently, then click OK.
- Click OK at prompts.
- Change User to Administrator, then click Login.
- Navigate to Management>Maintenance.
- Click on box next to Unit 0. A checkmark will appear.
- Click on Verify Unit.